Contents Up Previous Next

CHECK PC MC COMMUNICATION

Check communication from control to module test data Fragmentation is required.

Fragmentation is not mandatory for the operation and/or testing of the module.


  1. Send first fragment of test data to module.
  2. Wait for Bestätigung.
  3. Send second fragment of test data to module.
  4. Wait for Bestätigung.
  5. Send third fragment of test data to module.
  6. Wait for Bestätigung.
  7. Send last fragment of test data to module.
  8. Module acknowledges receipt of test data and identifies the data that has been interpreted incorrectly (all data OK). The ,,MsgCount'' is incremented by 1.

D-Len Cmd Data State/MsgCount
M->S 0x15 0x84 0xE5 0x19 0x04 0x9E 0xBF 0xA4
S->M 0x02 0x87 0x15 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x20 0x04
M->S 0x0F 0x85 0x70 0x3C 0x42 0x44 0x33 0x22
S->M 0x02 0x87 0x0F 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x20 0x04
M->S 0x09 0x85 0x11 0xCC 0xDD 0xEE 0xFF 0x00
S->M 0x02 0x87 0x09 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x20 0x04
M->S 0x03 0x86 0x02 0xFE 0xAF 0x?? 0x?? 0x??
S->M 0x04 0xE5 0x4F 0x4B 0x00 0x?? 0x?? 0x?? 0x?? 0x?? 0x?? 0x20 0x05