CHECK MC PC COMMUNICATION (Float)

Check communication from module to control with test data.

  1. Request test data from module (floating point value -1.2345).
  2. Test data is sent by module.

ID D-Len Cmd Data CRC16
M->S 0x05 0x01 0x03 0xE4 0x01 0x01 0xBD 0xB6
S->M 0x07 0x01 0x07 0xE4 0x19 0x04 0x9E 0xBF 0x01 0x01 0x74 0x37