Contents Up Previous Next

CHECK PC MC COMMUNICATION

Check communication from control to module with test data. Fragmentation is required.

Fragmentation is not mandatory for the operation and/or testing of the module.


  1. Send first fragment of test data to module.
  2. Send second fragment of test data to module.
  3. Send third fragment of test data to module.
  4. Send last fragment of test data to module.
  5. Module acknowledges receipt of test data and identifies the data that has been interpreted incorrectly (all data OK)

ID DLC D-Len Cmd Data
M->S 0x501 0x08 0x15 0x84 0xE5 0x19 0x04 0x9B 0xBF 0xA4
M->S 0x501 0x08 0x0F 0x85 0x70 0x3C 0x42 0x44 0x33 0x22
M->S 0x501 0x08 0x09 0x85 0x11 0xCC 0xDD 0xEE 0xFF 0x00
M->S 0x501 0x05 0x03 0x86 0x02 0xFE 0xAF
S->M 0x701 0x05 0xE4 0x4F 0x4B 0x00