CHECK MC PC COMMUNICATION (Float)
Check communication from module to control with
test data
.
Request
test data
from module (floating point value -1.2345).
Test data is sent by module.
ID
D-Len
Cmd
Data
M->S
0x501
0x04
0x03
0xE4
0x01 0x01
S->M
0x701
0x08
0x07
0xE4
0x19 0x04 0x9E 0xBF 0x01 0x01