Contents Up Previous Next

CHECK MC PC COMMUNICATION (Float)

Check communication from module to control with test data.

  1. Request test data from module (floating point value -1.2345).
  2. Test data is sent by module.

ID D-Len Cmd Data
M->S 0x501 0x04 0x03 0xE4 0x01 0x01
S->M 0x701 0x08 0x07 0xE4 0x19 0x04 0x9E 0xBF 0x01 0x01