Contents Up Previous Next

SET TARGET VEL (0xA0)

Code: 0xA0
Description: The velocity parameter is now set.
Parameter (master -> slave):

Response (slave -> master): ,,OK'' (0x4F4B) if successful.
Example:

D-Len Cmd Param
M->S 0x05 0xA0 0x33 0x33 0x43 0x41 Will set velocity to 12.2 [(mm)/(s)]
S->M 0x03 0xA0 0x4F 0x4B

Note: After first successful configuration, this value remains stored until the module is restarted or the value is changed. Required for ,,MOVE POS'', ,,MOVE POS TIME'', ,,MOVE POS REL'', ,,MOVE POS TIME REL'', ,,MOVE POS LOOP'', ,,MOVE POS TIME LOOP'', ,,MOVE POS REL LOOP'', ,,MOVE POS TIME REL LOOP''.