Code: 0xA0
Description: The velocity parameter is now set.
Parameter (master -> slave):
Response (slave -> master): ,,OK'' (0x4F4B) if successful.
Example:
| D-Len | Cmd | Param | ||
| M->S | 0x05 | 0xA0 | 0x33 0x33 0x43 0x41 | Will set velocity to 12.2 [(mm)/(s)] |
| S->M | 0x03 | 0xA0 | 0x4F 0x4B |
Note: After first successful configuration, this value remains stored until the module is restarted or the value is changed. Required for ,,MOVE POS'', ,,MOVE POS TIME'', ,,MOVE POS REL'', ,,MOVE POS TIME REL'', ,,MOVE POS LOOP'', ,,MOVE POS TIME LOOP'', ,,MOVE POS REL LOOP'', ,,MOVE POS TIME REL LOOP''.