Reference

Type

Access rights: Profi
Description: Enter here the referencing method to be used (When using encoders with the index track, please observe instructions in chapter (Pos Type).).

After a successful execution of the manual referencing, the referencing type is set to ,,Manual''.


Daten: (UInt16) 0 .. 65535

Max. Reference Current

Zugriffsrechte: Profi
Beschreibung: Current as [%] of the nominal current. The reference current stays below this value.
Daten: (UInt8) 0 .. 255

Velocity

Access rights: Profi
Description: Rated velocities for reference movements with internal or external reference switches and for velocity reference movements. This parameter is true for the manual referencing too and means 100% velocity.

If, after referencing, the module is to be moved to position ,,0.0'' the positioning command is executed with the velocity specified here.
Data: (4 bytes) Configured in the preset unit system.

Acceleration

Access rights: Profi
Description: Acceleration values for reference movements with internal or external reference switches, for velocity reference movements and manual referencing. If, after referencing, the module is to be moved to position ,,0.0'' the positioning command is executed with the acceleration specified here.
Data: (4 bytes) Configured in the preset unit system.

Offset

Access rights: Profi
Description: Position offset after successful referencing (zero point adjustment)
Data: (4 bytes) Configured in the preset unit system.

Move Zero After Referencing

Access rights: Profi
Description: After successful referencing, the module is moved to position ,,0.0''. The specified velocity and acceleration are adhered to.
Data: (Bool) TRUE / FALSE

Timeout

Access rights: Profi
Description: Maximum time for the reference movement.
Data: (Float) [s] or [ms], depending on unit system